接收并檢測質量流量控制器,并對其進行外觀檢查。
質量流量控制器信息錄入系統,生成一個工藝單,匹配適當的標準和適用的校準數據。
如果需要,預校準數據將被記錄并提供 (附加費用)。
質量流量控制器完全拆開、清洗
更換所有密封件并對質量流量控制器重新組裝
傳感器電流與硬件調整。
所有的電子部分/機械部分調整都需要滿足客戶的要求。
質量流量控制器測試是否漂移。
按原廠標準進行預檢漏測試。
由校準系統自動出具COC證書
包裝及運輸
質量流量控制器在防靜電包裝袋中密封。
證書與流量計再次進行裝袋密封。
我們服務全部按高標準質量控制系統來進行。
我們的清潔和校準程序分為四個過程:(1)清洗,(2)組裝,(3)校準,(4)裝運
The mass flow controller is received and visually inspected for damage.
The mass flow controller is logged into our computer, which generates a worksheet displaying the proper standard and applicable calibration data.
If requested, pre-calibration data is taken and graphed per customer request (additional fee).
The mass flow controller is disassembled and chemically and ultrasonically cleaned.
All seals are replaced and the mass flow controller is re-assembled
The sensor current and bypass adjustments are made.
All electronic/mechanical adjustments required to meet the customer specifications are made.
The mass flow controller is tested for long-term drift.
Calibration is performed at each calibration point with a calibration cover installed.
Pre-shipment leak testing to the manufacturer’s specifications is performed.
A Certificate of Calibration summarizing the calibration data and repair report is generated for your analysis and records.
Packaging and Shipping
The mass flow controller is doubled bagged in anti-static sleeving, and sealed. (All removed parts are sealed and returned in a separate bag).
The mass flow controller is then, double wrapped with bubble wrapping, boxed and packed with Styrofoam.
We utilize a unique (100% in-process) Quality Control System. Our Clean & Calibration procedures are divided into (4) processes:
(1) Cleaning, (2) Assembly, (3) Calibration and, (4) Shipping
Each process is inspected for defects or faults before it is transferred to the next station.